往复运动镍钛锉根管预备成形能力的体外研究Comparison of the shaping capability of reciprocating instruments in simulated canals in vitro邵 彤菲, 侯 晓玫, and 侯 本祥Guest Editor (s): 吴 爱华Author information Article notes Copyright and License information PMC Disclaimer首都医科大学附属北京口腔医院牙体牙髓科,北京 100050, Dept. of Endodontics, Beijing Stomatological Hospital, Capital Medical University, Beijing 100050, ChinaCorresponding author.[作者简介] 邵彤菲,住院医师,硕士,E-mail:moc.621@217iefgnot[通讯作者] 侯本祥,教授,博士,E-mail:moc.liamg@gnaixnebuohReceived 2014 May 20; Revised 2014 Sep 23Copyright 2014年版权归《华西口腔医学杂志》编辑部所有 本刊发表的文章文责由者自负Copyright © 2014 by Editoral Department of West China Journal of Stomatology All articles published represent the opinions of the authorsAbstract目的

比较4种机用镍钛器械预备树脂模拟弯曲根管的成形能力,为临床应用提供实验依据。

方法

40个单弯树脂模拟根管随机分为4组,每组10个,分别使用Reciproc(组1)、WaveOne(组2)、Mtwo(组3)和ProTaper(组4)进行根管预备,记录4组的预备时间,测量预备后根管的工作长度;使用扫描仪获取4组预备前后的根管图像,使用Photoshop和 Image J软件进行图像重叠并测量预备后根管弯曲角度的变化值,从距根尖孔1 mm开始,每隔1 mm测量根管内外侧壁树脂去除量,共10个测量点,计算中心定位能力。使用单因素方差分析、Kruskal-Wallis检验和SNK检验进行统计学分析,检验水准为双侧α=0.05。

结果

组2预备时间最短,为(53.7±6.7)s,组1、组3和组4分别为(86.9±8.1)、(112.2±8.2)、(177.9±11.2)s,4组间差异有统计学意义(P0.05)。组1、组2、组3、组4根管弯曲角度变化值分别为(2.671±0.637)° 、(2.667±0.450)°、(3.664±0.870)°、(3.797±0.601)°,组1和组2的变化值显著小于组3和组4(P